SQ-R Discharge Measurement System
The SQ-R sensor is a continuous measurement device for the contact-free determination of the water discharge of open or closed canals.
More information
Physical and environmental |
|
Power supply |
9...28 VDC; Reverse voltage pro- tection, overvoltage protection |
Power consumption at 12 VDC |
1.5 Ah per day Peak current drain 91 mA Inrush current <200 mA (for a measurement interval of 60 s) |
Outputs |
RS-485 ASCII / Modbus RTU SDI-12 Analog output 4…20 mA (14 bit, max. load 250 Ω) Digital output (low: 0V, high: Vsup- ply, max. 1.5 A) |
Operating tem- perature |
-40…60 °C (-40…140 °F) |
Storage temperature |
-40…60 °C (-40…140 °F) |
Relative humidity |
0...100 % |
Protection rating |
IP 68 |
Lightning protection |
Integrated protection against indir- ect lightning with a discharge capa- city of 0,6 kW Ppp |
Housing material |
Zytel 103HSL NC010, resistant to aggressive substances typically found in sewage channels |
Mounting bracket |
Mounting cube Ø30 mm |
Size L x W x H |
272 x 152.2 x 185.5 mm (10.71 x 5.99 x 7.30 in), including mounting cube |
Weight |
1.55 kg (3.42 lb) |
Velocity |
|
Detectable meas- urement range |
0.08…16 m/s (depending on waves) |
Accuracy |
± 0.01 m/s (certified by METAS) |
Resolution |
1 mm/s |
Direction recognition |
+/- |
Measurement dur- ation |
5…240 s |
Measurement interval |
8 s…5 h |
Measurement fre- quency |
24 GHz (K-Band) |
Radar opening angle |
12° |
Distance to water sur- face |
0.05…35 m (0.16114.83 ft) |
Vertical inclination |
Measured internally |
Automatic vertical angle compensation |
|
Accuracy± 1 ° |
|
Resolution |
± 0.1 ° |
Water level |
|
Measurement range (distance between level sensor and water surface) |
0.05…8 m (0.16…26.25 ft) |
Accuracy |
≤ 2 mm |
W-band (80 GHz tech- nology) |
W-band (80 GHz) |
Opening angle |
8° |
The SQ-R sensor is a continuous measurement device for the contact-free determination of the water discharge of open or closed canals. It combines two sensors in one system. The first determines the water level by measuring the transit time of a radar signal, the second simultaneously measures the flow velo- city of the water surface by means of the Doppler frequency shift. Following each measurement, the sensor applies an advanced hydraulic model to compute the mean velocity, which in turn is used to calculate the water discharge.
Due to the contact-free measurement method the SQ-R can be installed on extension arms without costly structural measures in the water or sewage treatment canal. This also has the advantage that the sensor is located outside the danger area of floods and that it requires virtually no maintenance over many years.
-
SQ-R Brochure
-
SQ-R Datasheet
-
SQ-R Manual